Bionnovation Biomedical Surgitime Titanium Seal Membrane
Bionnovation Biomedical Surgitime Titanium Seal Membrane is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
60 Days Money-back Guarantee
60 Days Money-back Guarantee
If your purchase doesn't meet your expectations, feel free to request a return within 60 days of receiving it.
Delivery and Shipping
Delivery and Shipping
U.S. DOMESTIC
Shipping Carriers | Shipping Cost | Estimated Delivery Time |
|
---|---|---|---|
USPS Ground | Free | 7-15 Business days | |
UPS® Ground |
$15
(Free on Orders Over $299) |
7-10 Business days | |
FedEx Standard |
$15
(Free on Orders Over $299) |
7-10 Business days | |
UPS® Priority |
$30
(Free on Orders Over $499) |
3-5 Business days | |
FedEx Express Saver® |
$30
(Free on Orders Over $499) |
3-5 Business days |
INTERNATIONAL SHIPPING
Shipping Carriers | Shipping Cost | Estimated Delivery Time |
|
---|---|---|---|
USPS First Class Package International |
$20
(Free on Orders Over $199) |
7-21 Business days | |
UPS Worldwide Expedited® |
$45
(Free on Orders Over $499) |
3-4 Business days | |
DHL Worldwide |
$45
(Free on Orders Over $499) |
2-3 Business days |
Don't want to miss out?
Join our community of dental professionals to receive updates
on exclusive deals
- Sizes: 34.0x25.0
-
Thickness: 0.4mm
- Material: PURE Titanium Gr 1 [ASTM F-67]
- Qualities: Exceptional Biocompatibility, Complete Waterproofing, Extremely Low Biofilm Retention, Easy Removal, Self-Fixing Capability
- Sterilization Type: Gamma Radiation
- Country of Manufacture: Brazil
Surgitime Titanium Seal stands as the optimal choice for intentional exposure in post-extraction alveolar sealing procedures, safeguarding surgical wounds against soft tissue invagination and fostering the reabsorption of the alveolar process. The modeled application ensures coverage of the operative area with a margin ranging from 2 to 4 mm.
Made from PURE Titanium Gr 1 [ASTM F-67], a material esteemed for its safety and efficacy in diverse surgical contexts, these seals undergo sterilization through Gamma Radiation [25kGy]. Surgitime Titanium Seal excels in biocompatibility, and imperviousness, and acts as a formidable barrier, preventing the intrusion of soft tissues over grafts and bone defects.
Adhering to stringent sterilization protocols and utilizing proper instrumentation is imperative. Professionals must discerningly choose the implementation site, considering its aesthetic impact. The malleability of Surgitime Titanium Seal facilitates effortless adaptation to surgical sites, while its bioelectric neutrality, achieved via electrochemical passivation, fosters unimpeded new bone growth. When sealing newly created sockets, the minimum stay required for osteoconduction commencement is lowered to 14 days, In other applications, the standard minimum stay for optimal osteoconduction commencement is 21 days.
Features:
- Enhanced Tissue Insulation - Ensures optimal protection for the surgical site.
- Self-fixing Capability - Allows for secure placement without the need for extensive fixation methods, enhancing the efficiency and ease of use in various surgical scenarios.
- Total Occlusivity - provides a fully sealed area that remains isolated and protected, promoting the success of the surgical procedure and reducing the potential for complications.
- Facile Removal- Efficient and straightforward removal when the healing process is complete, minimizing patient discomfort and aiding in overall procedural efficiency.
- Remarkably Low Biofilm Retention- reduces the risk of bacterial buildup, enhancing the overall hygiene of the treated area and contributing to a healthier healing environment for the patient.